Mark VI Speedtronic Control Cards

Following are the Mark VI Replacement Parts we stock or source. If you are interested in a part that is not listed here, please call to see if we service and supply it. DS200 Cards quoted in 08 and 09.

Mark VI Speedtronic Control Cards Mark VI Speedtronic Control Cards

MARK VI, IS200 & IS215 CARDS & POWER SUPPLIES
PART NUMBER DESCRIPTION
IS200DACBG1A AC DC CONVERTER
336A5199AAP /RM OBS – RESTRICTED – CALL CAROL STREAM
IS200DAMEG1A PULSE AMPLIFIER CARD
IS200DRLYH1A TERMINATION BD. RELAY (*2)
IS200DSPXH2D DRIVE DSP CONTROL CARD
IS200DTAIH1A DIN RAIL CONTACT INPUTS (*6)
IS200EACFG1A BOARD – EX2100 AC FE
IS200EACFG1B EX2100 AC FEEDBACK
IS200EACFG2A BOARD – EX2100 AC FE
IS200ECTBG1A TERMINAL BD – EX2100
IS200ECTBG2A EXCITER CONTACT TERM BOARD
IS200EDCFG1A USE IS200EDCFG1B/EX
IS200EDCFG1B EX2100 EXCITER DC FEEDBACK
IS200EDEXG1A USE IS200EDEXG1B/EX
IS200EDEXG1B EXCITER DE-EXCITATION EX2100
IS200EGDMH1A CARD-EX2100 GND DETE
IS200EGPAG1A CARD-EX2100 GATE PULSE
IS200EGPAG1B CARD-EX2100 GATE PUL
IS200EHPAG1C HV PULSE AMPLIFIER
IS200EHPAG1D HV PULSE AMPLIFIER
IS200EISBH1A EXCITER IN-SYNCH-BUS
IS200EMCSG1A CONDUCTION SENSOR PWA
IS200EMIOH1A CARD – EX2100 MAIN I/O
IS200EPCTG1A CARD-EX2100 EPCT EXC
IS200EPDMG1B EXCITER PWR DIST MODULE (*2)
IS200EPMCH1A EPMC CARD
IS200EPSMG1A EX2100 – POWER SUPPLY
IS200EPSMG2A EXCITER POWER SUPPLY (*2)
IS200ERDDH1A DYNAMICS DISCHARGE (*2)
IS200ERGTH1A EX2100 REG GND DETEC
IS200EROCH1A EXCITER REGULATOR OPTIONS CARD
IS200ERSCG2A USE IS200ERSCG2A
IS200ESELH1A EX2100- SELECTOR CARD
IS200EXAMG1A BOARD-EXCITER ATTENUATION MOD
IS200EXCSG1A EX2100 – CONDUCTION S
IS200EXHSG1A EX2100- H.S. RELAY DRIVER
IS200EXHSG2A EX2100 – EXCITGER H S RELAY DR
IS200EXHSG3A EX2100 – EXCITGER H S RELAY DRIVER
IS200EXHSG4A EXCITER H S RELAY DRIVER
IS200EXICH1A EX2100 – EXCITER CONTROL
IS200EXTBG1A EX2100 – EXCITER CARD
IS200FHVBG1 USE IS200FHVBG1A/EX
IS200FHVBG1A HIGH VOLTAGE GATE IN (*2)
IS200HFPAG1A HF AC SUPPLY
IS200JGPAG1A GROUND TERMINAL BD (*7)
IS200JPDAG1A AC PDM (*2)
IS200JPDBG1A AC PDM PCB
IS200JPDDG1A DC PDM
IS200JPDEG1A PDM 24/48VDC CARD
IS200JPDHG1A HD 28 V DISTRIB
IS200JPDMG1A 28V DC PDM
IS200PSCDG1A EX2000 PWM PS & CONT. DR
IS200SHRAH2A HART I/O TB
IS200SPROH1A PPRO TERMINAL BOARD
IS200SRLYH2A SIMPLEX TB RELAY
IS200SRTDH2A DRL TERM BD RTD
IS200STAIH2A DINRAIL TRBD ANLGIO
IS200STCIH2A DIN RAIL CONTACT INPUT CARD
IS200STTCH2A DINRAIL TB THERMOCOUPLE
IS200TAMBH1A ACOUSTIC MONITORING
IS200TBAIH1B TERM. BOARD, ANALOG INPUT
IS200TBAIH1C TERM. BOARD TRIP PRIM
IS200TBAIH2C TERM BD, ANALOG INPUT (*2)
IS200TBAOH1C TERM BOARD, ANALOG INPUT (*2)
IS200TBCIH1B TERMINATION BOARD
IS200TBCIH1C TERMIN.BD, CONTACT INPUT(*2)
IS200TBCIH2B TERMINATION BD., CON
IS200TBCIH2C TERMIN BD,CONTACT INPUT (*2)
IS200TBCIH3C TERM BD, CONTACT INPUT(*2)
IS200TBTCH1B THERMOCOUPLE TERM BD
IS200TBTCH1C THERMOCOUPLE TERMINAL BOARD
IS200TGENH1A TERMINATION BD, GENE
IS200TICIH1A TB ISOLATED CONTACT
IS200TICIH2A TB ISOLATED CONTACT INPUT
IS200TPROH1B TERMINATION BD. PROTECTIVE
IS200TPROH1B TERMINATION BD., PROTECTIVE
IS200TREG1B TERMINATION BOARD, TRIP EMERGENCY
IS200TREGH1A TERM. BD., TRIP EMER. GAS
IS200TREGH1B TERM. BD., TRIP EMER
IS200TREGH2B TERM BD, TRIP EMER
IS200TRESH1A TERM BD TRIP EMERGENCY
IS200TRLYH1B TERMINATION BOARD, RELAY
IS200TRLYH2E TERMINATION BOARD, RELAY
IS200TRLYH2E TERMINATION BOARD, RELAY
IS200TRLYH1C RELAY, TERM. BOARD
IS200TRLYH1D TERMINATION BD,RELAY
IS200TRLYH1E TERMINATION BOARD, RE
IS200TRLYH2E TERMINATION BOARD, RE
IS200TRPGH1A TERM. BD., TRIP PRIMARY GAS
IS200TRPGH1B TERMINATION BOARD, TRIP PRIM
IS200TRPGH2B TERM BD., TRIP PRIMARY GAS
IS200TRPAH1B TERN BD., TRIP PRIMARY GAS
IS200TRPSH1A TERM BD TRIP PRIMARY
IS200TRTDH1A USE IS200TRTDH1C/EX
IS200TRTDH1B MARK VI,RTD TERMINAL CD-TMR VERSION
IS200TRTDH1C MARK VI, RTD TERMINAL
IS200TRTDH1C MARK VI,RTD TERMINAL CD-SIMPLEX VER
IS200TRTDH1D MARK VI,RTD TERM BD(*2)
IS200TRTDH2D MARK VI,RTD TERMIN CD
IS200TSVAH1A TMR SERVO TERMINAL BD
IS200TSVCH2A SERVO TERM BD
IS200TSVCH2B SERVO TERM BD
IS200TSVOH1B TERMINATION BOARD. SERVO
IS200TTPWH1A P28VDC DISTRIBUTION
IS200TTURH1B TERMINATION BOARD TURBINE
IS200TTURH1C TERMINATION BOARD
IS200TVIBH2B TERMINATION BOARD, VIBRATION
IS200VAICH1C VME ANALOG INPUT CARD
IS200VAICH1D VME ANALOG INPUT CARD
IS200VAOCH1B VME ANALOG OUTPUT CARD
IS200VAOCH1C VME ANALOG OUTPUT CARD (*2)
IS200VCCCH1B MARK VI CONTACT COMBO CARD
IS200VCMIH2B USE IS215VCMIH2B
IS200VCRCH1B CONTACTS IN, RELAYS OUT
IS200VGENH1B VME GENERATOR
IS200VRTDH1C USE IS200VRTDH1D/EX
IS200VRTDH1D MARK VI, VME RTD CARD
IS200VSVOH1B VME SERVO CARD
IS200VTCCH1C MARK VI THERMOCOUPLE CARD
IS200VTURH1B VME TURBINE CARD
IS200VTURH2B VME TURBINE CARD
IS200VVIBH1C VME VIBRATION CARD
IS2020DRLYH1AA CARD ASSEM. DRLY PLA
IS210DRTDH1A CARD ASSEM. DRTD RAI
IS210DSVOH1A CARD ASSEM. DSVO RAI
IS210DTRTH1AA CARD ASSEM. DTRT RAI
IS2020DRLYH1BA CARD ASSEM.DRLY PLATE MTG.
IS2020ISUCG3A 00PIN/BASE MTD/UNIT CONTROLLER
IS2020JPDCG01 PDM, DC POW. DIST.
IS2020JPDCG02 PDM, DC POW. DIST. MODULE
IS2020LVPSG1A DNS POWER SUPPLY 12 V
IS2020LVPSG2A POWER SUPPLY/MARK V/NO-335V
IS2020RKPSG1AI SEE NOTES-SUB IS EITHER 2A OR 3A
IS2020RKPSG1AK SEE NOTES-SUB IS EITHER 2A OR 3A
IS2020RKPSG2A POWER SUPPLY/MARK VI/WITH-335V
IS2020RKPSG3A POWER SUPPLY/MARK VI/NO-335V
IS210DRTDH1AA CARD ASSEM. DRTD RAI – NOTES
IS210DSCBH1A CARD ASSEM DSCB RAI
IS210DSVOH1AA CARD ASSEM. DSVO RAI
IS210DTAIH1AA CARD ASSEM. DTAI RAI
IS210DTCIH1AA CARD ASSEM. DTCI RAI
IS210DTRTH1AA CARD ASSEM. DTRT RAI
IS210DTTCH1AA CARD ASSEM. DTTC RAI
IS210DTURH1AA CARD ASSEM. DTUR RAI
IS215ACLEH1A USE IS215ACLEH1B/EX
IS215UCVDH2A UC2000/VME P233/1
IS215UCVDH5AN UC2000/VME P133/2 GENIUS 10B-T
IS215UCVEH2A VME CONTROLLER CARD-VMIC
IS215UCVEM01A UCVEH2A+2ND ETHERNET
IS215UCVFH2A RESTRICTED
IS215UCVGH1A VME CONTROLLER CARD-VMIC
IS215UCVGH1A RESTRICTED
IS215UCVGM06A CONT. WITH 2 ISBUS CHANNELS
IS215VCMIH1B IF AVAIL OR USE # PK-IS215VCMIH1B/EX
IS215VCMIH1C VME COMM INTERFACE
IS215VCMIH2B IF AVAIL OR USE PK-IS215VCMIH2B/EX
IS215VCMIH2C VME COMM INTERFACE CD
IS215VPROH1A USE IS215VPROH1B
IS215VPROH1B VME TPROTECTION ASSEMBLY
IS215VPROH1B VME PROTECTION ASSEM.
IS215VPROH2B VME PROTECTION ASSEM.
P-IS215VCMIH1B PK FOR OBS VCMIH1B-VME COMM ASM
P-IS215VCMIH2B PK FOR OBS VCMIH2B-VME COM INTERFACE CD
IS230JPDS1AG01 POWER DISTRIBUTION MODULE, 28VDC
IS230SRTD2ASRTD2AG01 I/O MODULE, “S”, RTD, TWIN
IS230SRTD2ASRTD2AG11 I/O MODULE, “S”, 0-20MA
IS230STAI2ASRTD2AG01 I/O MODULE, “S”, PLUG TB RTD 0-20MA
IS230STAI2ASTAI2AG21 I/O MODULE, “S”, 0-20MA, TWIN S&T
IS230STAI2ASTAI2AG01 I/O MODULE, “S”, RTD, TWIN
IS230STAI2ASRTD2AG02  
IS230STAI2AG01  
IS230STTC2ASTTC2AG11  
IS230TBAI1CH02  
IS230TBAI1CG01  
IS230TBAICG01  
IS230TBCI2CG01  
IS230TBCI2CG01  
IS230TEFV1AG01  
IS230TRLY2EG01  
IS230TRLY3EG01  
IS230TRPA1AG01  
IS230TSVC2AG01  
IS230TSVC2AG01  
259B2431XCG01  

* Speedtronic and Directomatic are trademarks of the General Electric Company.

Having given more than thirty years of success and experience to the turbine control system industry, General Electric is widely renowned as the leader in such technology. Whether currently using the Mark V, Mark VI or the VIe control system, your control cards are the central nervous system behind the very heart of your operations. When setting up a new system, some factors are key.

What is required of your turbine controls? Can you shut down your entire Speedtronic system for repairs and maintenance, or do you require constant up-time? A less expensive SIMPLEX control system may serve your purpose well as long as all components are functioning normally; however, if any major component malfunctions, you may be facing a complete system shutdown until the necessary repairs are made. In cases where you can not afford a full blown cessation, a dual or triple redundant control system will be more suitable. This would allow the system to continue operating while repairs are performed or replacement of the faulty GE Mark VI control cards, or any of its predecessor controls, are completed.

Another vital factor is whether or not the company providing your control system offers the type of service and support you need after your purchase is complete. You may have a team of in-house programmers and service technicians; if so, this aspect may not be as important to you. Keep in mind, though, you will need replacement components from time to time. Be completely assured your supplier is able to send you any replacement parts when you need them.

If do not have your own support team, you need a guarantee your supplier can send out their own highly experienced team right away to take care of any problems you may have. Either way, after you purchase a Mark VI control system, you need to be sure the supplier can either ship you the appropriate IS200 replacement components or send a team of specialists who will have the right items.

Most experts insist cost should be the least important deciding factor regarding your turbine control system. Saving money on the control system means nothing if it is unreliable and replacement parts or field support teams are never available when needed. An initial cost reduction is also fruitless if you lose production due to a system that can not fully serve your purpose.